Welcome
User Manual - iQ WMR
User Manual - iQ WMR
  • Introduction
  • About this document
  • DEVICE
    • Device Overview
      • Installation
    • Technical Specifications
      • Bluetooth Low Energy (BLE)
    • Physical Interfaces
      • Power Supply
    • Operation
      • Application Operation
    • Registers
      • Generic Data
      • Device Data
      • LoRaWAN Data
  • LoRaWAN
    • LoRaWAN Communication
      • Payloads
        • Uplinks
        • Downlinks
  • Support and Maintenance
    • Troubleshooting
    • Maintenance
    • Changelog
Powered by GitBook
On this page
  • Generic Device Data
  • Internal Temperature Sensor
  • Temperature and Humidity Sensor
  1. DEVICE
  2. Registers

Generic Data

All devices manufactured by Yobiiq B.V. follow the same specification for generic data availability. This is done to have a consistent way for the configuration and maintenance of our devices.

The availability of Generic Data is based on the firmware version and hardware version from the specific end device you have. As such it's possible that certain data is not available in your device.

Generic Device Data

The following registers contain data with regards to the device.

Descriptive Name
Address
R/W
Default
Comment

Status

0x64

R

Status of the device.

Manufacturer

0x65

R

YOBIIQ B.V.

Returns the manufacturer of the device

OEM

0x66

R

Returns the name of the customer for which the OEM version was made

Model

0x67

R

Returns the model of the device

Serial Number

0x68

R

Serial number of the device

Firmware Version

0x69

R

Returns the firmware version

Hardware Version

0x6A

R

Returns the hardware version

External Power Status

0x6B

R

Status (AC Present / Not Present)

Battery Voltage

0x6C

R

Battery Voltage

Battery Percentage

0x6D

R

Battery percentage

Password

0x6E

R/W

Password for logging on the device using Toolbox (possibility to change password within Toolbox)

Restart

0x6F

W

Restart the device

Internal Temperature Sensor

The internal temperature sensor is fitted to protect the device against overheating, the temperature/humidity values are not considered to be usefull for any other means.

Descriptive name
Address
R/W
Default Value
Comment

Temperature Error

0x78

R

Returns the current alarm state. 0 = No Error 1 = Error

Number of temperature alarms

0x79

R

Saved in flash memory, non-resetable.

Internal Circuit Temperature

0x7A

R

Internal Circuit temperature measurement value

Internal Circuit Humidity

0x7B

R

Internal Circuit Relative humidity measurement value.

The temperature error is activated if the measured temperature or humidity exceeds the listed operation conditions.

Temperature and Humidity Sensor

Some of our devices are equipped with a Temperature and Humidity sensor to reflect ambient environment measurements.

Descriptive name
Address
R/W
Default Value
Comment

Internal Temperature

0x82

R

Internal temperature measurement value

Internal Humidity

0x83

R

Internal Relative humidity measurement value.

PreviousRegistersNextDevice Data

Last updated 6 months ago