Uplinks
Generic Device Information
The device sends an uplink containing generic device information following a succesfull network join. The generic device information is send over fPort 50.
ff
00 (Status)
Status of the device
01 (Manufacturer)
Hex of the manufacturer
02 (Model)
Hex of the model
03 (Device SN)
7 digits serial number
11 (Device Class)
0x00: Class A, 0x01: Class B, 0x02: Class C
06 (Power Event)
0x00: AC Power Off, 0x01: AC Power On
05 (Hardware Version)
Hardware version, example 0100 is version 1.00
04 (Firmware Version)
Firmware version, example 0100 is version 1.00
07 (Battery Voltage)
Battery Voltage
08 (Battery Percentage)
Battery Percentage
Alarms
If an alarm occurs within the device an uplink message is immediately send over fPort 11. The message contains the register number of the alarm and the current value.
0xAA
0xFE
Current timestamp of the device, taken from device RTC.
0xAA
0x00
0xAA
0x01
LoRaWAN watchdog alarm 0x00 : normal 0x01 : alarm
0xAA
0x78
Internal Temperature Sensor Alarm 0x00 : normal 0x01 : alarm
Periodic Transmissions
Last updated